Outdoor Air Quality Test Kit With Series 500 Monitor
Outdoor Air Quality Test Kit With Series 500 Monitor
The Aeroqual Outdoor Air Quality Test Kit (Starter) includes everything you need to start measuring key pollutants commonly found in urban environments. Features Aeroqual’s proven Series 500 portable monitor with interchangeable sensor heads, measuring particulate matter (PM2.5, PM10), nitrogen dioxide (NO2), and ozone (O3), along with a combined temperature and relative humidity sensor. Suitable for use during outdoor air quality assessments, personal exposure monitoring, and as an educational tool.
Consider choosing an Indoor Air Quality Test Kit with a Ranger Portable Air Monitor.
Includes swappable sensor heads for each of the three main air pollutants found in urban environments – particulate matter (PM2.5, PM10), nitrogen dioxide (NO2), and ozone (O3)
Gather data in real-time using the Series 500’s inbuilt real-time data logger
Long-life lithium battery and in-field calibration make this an easy-to-use kit, delivering highly accurate results
Product overview
The Outdoor Air Quality Test Kit (Starter) features industry-quality instruments used by researchers and air quality professionals around the world in an affordable, easy-to-use package. Simply swap out the sensor head on the Series 500 portable monitor for the pollutant you wish to monitor. Nitrogen dioxide (NO2) and particulate matter (PM) are emitted directly by stationary vehicles, and ozone (O3) is created when NO2 and volatile organic compounds (VOCs) combine in the presence of sunlight. The health risks of overexposure to these pollutants are well-documented. This kit also includes a combined temperature and relative humidity sensor.
Protect yourself and your community, learning more about the quality of your outdoor air. For a full set of tools, including additional sensor heads measuring CO and VOCs, see the Outdoor Air Quality Test Kit (Pro).
What can it measure?
The Outdoor Air Quality Test Kit (Starter) combines the Aeroqual Series 500 portable monitor with the following interchangeable sensors:
Particulate Matter Sensor (PM10, PM2.5)
Ozone Sensor 0-0.15ppm
Nitrogen Dioxide Sensor 0-1ppm
Temperature & Humidity Sensor
The Series 500 monitor also comes with:
LCD digital display
Lithium battery and charger
In-built datalogger
Monitor to USB cable
PC software
Small carry case
Key benefits of Aeroqual products
Industry-leading sensor technology
As sensor manufacturers, we know sensors inside and out and have unparalleled expertise in optimizing performance in real-world conditions.
Powerful software platform
Leveraging deep integration with our monitoring systems, we deliver software functionality unmatched by off the shelf data acquisition systems.
Value-adding services
Using proprietary system diagnostics, we enable proactive maintenance with hassle-free services that virtually eliminate system downtime.
Who is it for?
Researchers, air quality professionals, and community groups use the Outdoor Air Quality Test Kit (Starter) to conduct outdoor air quality assessments and to ensure sensitive receptors in the community are not at risk from air pollution.
Practical applications for the Outdoor Air Quality Test Kit (Starter) include:
Personal exposure monitoring
Outdoor air quality assessments
Educational learning tool
Checking pollution “hotspots”
Working with your sector
Related products
Case studies
Case Study - Remediation
Real-Time Monitoring Protects Communities During Reclamation Project on Nation’s Largest Municipal Utility
Case Study - Industrial Hygiene
Building a Reliable Air Monitoring Solution in Challenging Environmental Conditions in Iraq
Case Study - Remediation
Real-Time Air Monitoring Protects New Yorkers, Saves Time and Money During Expansion of Nation’s Busiest Commuter Rail Line
Specifications
S500 PC software download
Download the S500 Series PC software here.
FAQs
There are many different types of outdoor air pollution. Measuring them all would be too expensive, so regulators focus on a smaller group of common air pollutants, sometimes known as the criteria pollutants. The criteria pollutants are:
Nitrogen dioxide (NO2)
Sulfur dioxide (SO2)
Carbon monoxide (CO)
Ozone (O3)
Particulate matter (PM)
As always requirements should be confirmed with your local regulatory body.
Sensors are housed within an interchangeable ‘sensor head’ that attaches to the monitor base. You can choose from up to 28 different gas and particulate sensor heads. Each sensor head contains a single gas or particle sensor. Swapping sensor heads takes seconds and no configuration or re-calibration is required.
You can find our specifications for our sensor heads here:
Aeroqual-Portable-Fixed-Sensor-Specifications.pdf
Note: Accuracy may drift as the sensor ages.
Aeroqual recommends replacement after two years, however higher exposure levels or harsh environments can lead to a significant reduction in life expectancy. Your monitor display is likely to indicate Sensor Failure or Sensor Ageing if the sensor is nearing the end of its useful life.
Note: Sensor heads may degrade even when unused and in storage.
How many sensors can I use on the monitor at once?
You can only connect one gas or particulate sensor head at a time to monitor. However, you are able to connect the optional temperature and humidity sensor at the same time as a gas or particulate sensor head.
Can I use the PM sensor head with any portable monitor?
The PM sensor is compatible with Series 200/300/500 monitors with software version 6.4 introduced in November 2014.
What is the PPM to mg/m³ conversion factor?
PPM is an absolute measurement, whilst mg/m3 varies depending upon pressure and temperature. The portable monitor measures in PPM and applies a conversion factor if you wish to measure in mg/m3.
NH3 - 0.76, CO - 1.25, CO2 - 1.96, CL2 - 3.16, CH2O - 1.34, H2 - 0.082, CH4 - 0.72, H2S - 1.52, NO2 - 2.05, NMHC - 2.5, O3 - 2.14, C2CL4 - 6.78, SO2 - 2.86, VOC - 2.5, PM - N/A*
*as particulate matter varies in size, unlike a gas molecule, PPM is not a valid unit of measurement
Do I return the instrument for calibration?
Only the sensor head needs to be calibrated. The base unit does not need to be calibrated. All parameters are stored on the sensor head.
The sensor head calibration should be completed after the first year. Aeroqual does not recommend a second factory calibration, but rather replacement after two years of operation.
See a range of frequently asked questions on calibration here.
How long can I log data for (Series 500 only)?
The Series 500 handheld unit can store a limited number of data points (8188), meaning that the length of time that data can be logged depends upon the frequency and number of data points recorded. For example:
If you are logging every minute for one gas (i.e. one data point per minute) you can log for 8188 minutes.
If you are logging every minute for one gas, temperature and humidity (i.e. 3 data points per minute) you can log for 2729 minutes.
Decrease the logging frequency for the ability to log over a longer timeframe.
Note: Once capacity is reached new data will begin to overwrite the oldest logged data.
What communication options does the portable monitor have?
S200: None
S300: 0-5V Analog output (current reading only)
S500: 0-5V Analog output (current reading only), RS232 (current, logged data and instrument control) to PC software via USB adapter. RS232 protocol available upon request for third party software integration.
What is the “Control” function (Series 300 & 500 only)?
This is designed to control generation of a gas such as ozone from an ozone generator. The control pin can be wired to control a gas concentration between upper and lower concentration limits. The upper and lower limits can be set by the user via this control function.
Refer to the relevant section of the user guide for wiring instructions.
What accessories are available for the portable monitors?
Aeroqual offers a range of accessories to suit your application. See the range here.
Product Support
For support on your S Series instrument, click here to visit our support centre.
Air monitoring made easy
Take the time and hassle out of your next project with a real-time air quality monitoring solution.